innerbanner






img

Formation

70.0 to 240 sq mm generally conforming to IS 694

Color Codes

Red, Yellow, Blue, Black, Grey, White, Pink, Green, Violet, Brown, Orange

Flexible Wires / Cables IS:694

Working voltage

Upto 1100 V

Temperature Range

-15 deg C to +70 deg C

Sizes Covered

0.5 to 50.0 sq mm with ISI mark

Specification

IS 694:1990

BS 6004:1991 and BS 6500:1990 also available

Packing

In 100-meter coils. Higher sizes on drums

Area sq. mm
0.5
0.75
1.0
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
50.0
_
Conductor
No.& Size of Wire(Nom.)mm Max
16/.2
24/.2
32/.2
30/.25 OR 48/.2
50/.25 OR 80/.2
56/.3
84/0.3
80/0.4 OR 140/0.3
126/.4
196/.4
276/.4
396/.4
_
Max Resistance @ 20 ° C Ohm/Km
39.0
26.0
19.5
13.3
7.98
4.95
3.30
1.91
1.21
.078
0.55
0.38
_
Current Rating DC or AC
4
7
12
15
20
27
35
46
62
80
102
138
Insulation
Thickness (Nom.) mm
0.6
0.6
0.6
0.6
0.7
0.8
0.8
1.0
1.0
1.2
1.2
1.4
Single Core Unsheathed
Overall Diameter (mm)
2.20
2.45
2.60
2.90
3.55
4.20
5.20
6.70
7.80
9.70
10.9
13.20
Single Core Sheathed
Sheath Thickness (Nom.) mm
0.9
0.9
0.9
0.9
1.0
1.0
_
_
_
_
_
_
_
Overall Diameter (Approx mm)
4.0
4.25
4.5
4.80
5.45
6.30
_
_
_
_
_
_
Twin Flat Sheathed
Overall Width mm
6.2
6.7
_
_
_
_
_
_
_
_
_
_
_
Overall Height mm
4.0
4.25
_
_
_
_
_
_
_
_
_
_
2 Core
Sheath Thickness (Nom.) mm
0.9
0.9
0.9
0.9
1.0
1.0
_
_
_
_
_
_
_
Overall Diameter (Approx.) mm
6.5
7.0
7.3
7.8
9.5
11.0
_
_
_
_
_
_
3 Core
Sheath Thickness (Nom.) mm
0.9
0.9
0.9
0.9
1.0
1.0
_
_
_
_
_
_
_
Overall Diameter (Approx.) mm
6.9
7.4
7.7
8.2
10.0
11.5
_
_
_
_
_
_
4 Core
Sheath Thickness (Nom.) mm
0.9
0.9
0.9
0.9
1.0
1.0
_
_
_
_
_
_
 
Overall Diameter (Approx.) mm
7.5
8.0
8.5
9.5
11.0
13.0
           
5 Core
Sheath Thickness (Nom.) mm
0.9
0.9
1.0
1.0
1.0
1.1_
_
_
_
_
_
_
_
Overall Diameter (Approx.) mm
8.30
9.00
9.50
10.5
12.0
14.0
_
_
_
_
_
_
Note : Sheath thickness given are nominal, and overall diameters given are approximate.
The conductor strand diameters are in line with IS : 8130/1984.
The no. of wires indicated are approximate and diameter of strands is nominal and shall be such that it satisfies the requirements as per IS 694/1990. The conductor strand size and conductor resistance requirements as per IS 8130 will be satisfied.

Single Core Flexible Cables Generally Conforming To Is 694: 1990 Voltage Grade Upto 1100 Volts

AREA sq. mm.
70.0
95.0
120.0
150.0
185.0
240.0
NO. & SIZE OF WIRE
No./mm
360/.5
475/.5
608/.5
750/.5
925/.5
1221/.5
CONDUCTOR MAX RES. @200C
Ohms/km
0.272
0.206
0.161
0.129
0.106
0.0801
CURRENT DC/AC
Amps
214
260
305
355
415
500
INSULATION THICKNESS (Nom.)
mm
1.4
1.6
1.6
1.8
2.0
2.2
O.D. (Approx.)
mm
15.3
17.9
19.4
21.9
24.5
28.0
Cables upto 150 sq.mm. can also be supplied as per IS 2465 : 1984 with ISI mark
Conductor Cross Section mm Radial Thickness of insulation
(Nom.) mm
Cables with stranded conductor (H07V-R) Conductor construction No./size of wire mm Cables with stranded conductor (H07V-R) Cable OD (maximum) mm Cables with flexible conductor (H07V-K) Conductor construction No./size of wire mm Cables with flexible conductor (H07V-K) Cable OD (maximum) mm
Single Core Unsheathed Cables, 450/750v Dc And 690/1000v Ac
0.5
0.6
7/0.30
2.6
16/.2*
2.6
0.75
0.6
7/.37
2.8
24/.2*
2.8
1.0
0.6
7/.44
3.0
32/.2*
3.0
1.5
0.7
7/.53
3.5
30/.25
3.5
2.5
0.8
7/.67
4.2
50/.25
4.2
4.0
0.8
7/.85
4.8
56/.3
4.8
6.0
0.8
7/1.04
5.4
84/.3
6.4
10.0
1.0
7/1.35
6.8
80/.4
7.6
16.0
1.0
7/1.70
8.0
126/.4
8.8
25.0
1.2
7/2.14
9.8
196/.4
11.0
35.0
1.2
19/1.53
11.0
276/.4
12.5
50.0
1.4
19/1.78
13.0
396/.4
14.5
70.0
1.4
19/2.14
15.0
360/.5
17.0
95.0
1.6
19/2.52
17.0
475/.5
19.0
120.0
1.6
37/2.03
19.0
608/.5
21.0
150.0
1.8
37/2.25
21.0
750/.5
23.5
185.0
2.0
37/2.52
23.5
925/.5
26.0
240.0
2.2
61/2.25
26.5
1221/.5
29.5
*
Stranded conductor are Class 2 type, flexible conductors are Class 5 type as per BS 6360.
*
Cables upto and including 10.0 sq. mm. can be offered with rigid/solid Class 1 type conductors.
*
On specific request, cables of sizes 6.0 sq. mm. And above can be offered with Class 1 conductors.
   
 
Other types of cables offered for overseas markets include:
*
Multicore cables with stranded (Class 2), flexible (Class 5) and extra flexible (Class 6) conductors.
*
Single and multicore cables with PVC double sheet. 3 Core, PVC insulated and PVC flat-sheeted cables and PVC insulated winding wires for submersible pumps, 4 core flat cables also available.
*
Flexible auto cables as per BS 6346, and battery cables for automobiles, Auto cables as per DIN 72551 are also available.
*
PVC insulated power and control cables as per BS 6346, XLPE power cables as BS 5467 are also available.